Standard Health and Safety Features

Health and Safety has always been of paramount importance to Union Industries in the design of its Matadoor Range of Hi-Speed Doors.

As such it supplies the following safety devices and controls AS STANDARD and within the basic price for its Matadoor, Bulldoor and Ramdoor Hi-Speed Doors.

 

12 Standard Safety Features fitted to ALL Ramdoor, Bulldoor & Matadoors

1.

Double Photocells at ground level, one fore and one aft of the door line, to detect the presence of Pedestrians or equipment passing through the opening and prevent the door blade from closing or cause a closing blade to open.

2.

Foam packed Safety Buffers' attached fore and aft of the bottom bar providing padding under the metal pressings which form part of the bottom beam construction and protection to pedestrians who may accidentally turn towards a closing door blade.  

3.

Touch Sensitive Safety Edge Contact Strip running the full length of the bottom beam to retract a closing door blade when coming into contact with any obstruction.

4.

Counterweight Inspection Covers covering the inspection hatches to the counterweight chambers, supplied with ‘Danger' warning notices and anti-tamper ‘Torx' crews to prevent removal by any but authorised personnel.

5.

Manual Brake Release Mechanism to enable the door blade to be raised in the event of power failure complete with legend plate giving directions for use.

6.

Drive Chain & Pulley Guard (Additional infill and Non-Drive side Pulley Guard fitted to all doors of 2.500m. doors and under).

7.

Door Blade Fabric Fire Retardant to ISO 34A (BS 5438).

8.

Mechanical Protection given to all external cables.

9.

CE compliance - The Matadoor Range of Hi-Speed Doors complies with the essential Health & Safety requirements of the latest EC Machinery Directives. Control Panel EMC compliant.

10.

Counterweight System in conjunction with a superior Brake and Geared Motor Unit enables a descending blade to stop ‘dead' when triggered by any of the safety devices, and immediately retract to the fully open position.

11.

24 v.a.c. (low voltage) wiring. (excluding motor).

12.

ALL SAFETY DEVICES 'FAIL TO SAFE CONDITION'.
^back to top

Additional/Optional Safety Features

FOR PEDESTRIAN PROTECTION



OR PEDESTRIAN WARNINGS

There will be times when it is impracticable or impossible to accomodate the Stand-off Sensing Devices to both front and rear of the doorway, as recommended by the HSE for doors of pedestrian usage. In some instances only one side of the opening will lend itself to this type of protection and warning devices must be considered.

Alternatively there are sites where end users are already committed to a rigorous and exacting Health & Safety regime and whose policy it is to exceed the minimum safety requirement in their efforts to reduce accidents and avert the risk of litigious claims.

The following additional safety options are available, most of which are suitable for both Pedestrian and Forklift doorways.

Safety Cloak

(Secondary sensing device)

Manual Activation

Recommended for all doors where pedestrian usage is ALLOWED or UNAVOIDABLE.

Activation most suitable for manual ‘OPEN' and manual ‘CLOSE' operation include -

 
  • Pull Cord Switches
  • Radio Control
  • Push Button (Double Push Buttons or Red Mushroom)
  • Photocell

AUDIBLE WARNINGS

  • Sounders
    Typically fitted to the top of and link wired into the Control Panel to sound an alarm of the operation of the door in a variety of ways.

    e.g.
    To sound 2 seconds before the door blade closes and throughout the closing cycle.
    To sound continuously throughout the opening and closing cycles.

    NOTE - Account must be taken of existing sound levels when considering this device.

Visual Warnings

Link wired into the Control Panel to provide a variety of warning options in a similar manner to those of the Audible Warnings referred to above.

  • Flashing Beacons
    Typically fitted above head height and to both front and rear of the doorway to warn those approaching that the door is about to close.

  • Indicator Lights
    Typically Red and Green light unit fitted to one or both sides of a doorway or Airlock, to warn of oncoming traffic in a two-way system or to warn that an Airlock is in use.
     
  • Traffic Lights
    Heavyweight and larger version of the Indicator Lights above with Red and Green ‘Stop' and ‘Go' lights housed in a cowled bulkhead fitting. Typically fitted to external doorways to regulate and control the safe flow of traffic through the opening.
  • Warning Text
    In addition to the warning text recommended by the HSE for all non-pedestrian doors, it is good practice to include safety text on the blades of doors where pedestrian use is permitted or unavoidable to draw their attention to the fast acting operation of Hi-Speed Doors. The text should read -


DANGER
FAST ACTING DOOR

^back to top
Email: doors@unionindustries.co.uk
Tel: +44 (0) 113 244 8393 | Fax: +44 (0) 113 242 1307
Union Industries, Angel's Wing, Whitehouse Street, Hunslet, Leeds, LS10 1AD
ISO9001 Certificate No.SP240172 : IAB Registration No. 0044/1